"Muu" projekt VA621
VA621 "Uued standardid ja jälgitavus radiomeetrias (1.10.2013−30.09.2016)", Mart Tamre, Tallinna Tehnikaülikool, Tallinna Tehnikaülikool, Mehaanikateaduskond, Mehhatroonikainstituut, Mehhatroonikasüsteemide õppetool, Tallinna Tehnikaülikool, Mehaanikateaduskond, Mehhatroonikainstituut, Kvaliteeditehnika ja metroloogia õppetool.
VA621
Uued standardid ja jälgitavus radiomeetrias
New primary standards and traceability for radiometry
New primary standards and traceability for radiometry
1.10.2013
30.09.2016
Teadus- ja arendusprojekt
Muu
ValdkondAlamvaldkondCERCS erialaFrascati Manual’i erialaProtsent
4. Loodusteadused ja tehnika4.10. FüüsikaP180 Metroloogia, instrumentatsioon1.2. Füüsikateadused (astronoomia ja kosmoseteadus, füüsika ja teised seotud teadused)60,0
4. Loodusteadused ja tehnika4.12. Protsessitehnoloogia ja materjaliteadusT110 Instrumentatsioonitehnoloogia 2.3. Teised tehnika- ja inseneriteadused (keemiatehnika, lennundustehnika, mehaanika, metallurgia, materjaliteadus ning teised seotud erialad: puidutehnoloogia, geodeesia, tööstuskeemia, toiduainete tehnoloogia, süsteemianalüüs, metallurgia, mäendus, tekstiilitehnoloogia ja teised seotud teadused).20,0
4. Loodusteadused ja tehnika4.10. FüüsikaP200 Elektromagnetism, optika, akustika 1.2. Füüsikateadused (astronoomia ja kosmoseteadus, füüsika ja teised seotud teadused)20,0
AsutusRiikTüüp
Euroopa Komisjon
PerioodSumma
01.10.2013−30.09.201656 775,50 EUR
56 775,50 EUR
EMRP

"Projekt on suunatud optilise võimsuse ja sellest tuletatud SI ühikute realiseerimise uudsete meetodite arendustele nähtavas spektripiirkonnas ja lihtsustatud jälgitavuse skeemide väljatöötamisele lõpptarbija jaoks. Projekti eesmärgid saavutatakse radiomeetria primaaretaloni optimeeritud lahendusega nähtavas piirkonnas määramatusega 1 ppm ja jälgitavusahela parendamisega fotomeetrias ja kiirgustermomeetrias filter-radiomeetreid kasutades määramatusel 100 ppm. Seni on täpseimad mõõtmised radiomeetrias küündinud 30 ppm. Samuti kindlustatakse kiudoptiliste mõõtmiste määramatust 1000 ppm. Projekti peamine eesmärk on parendada ränidetektoril põhinevat primaaretaloni, millel on ligikaudselt sama maksumus ja funktsionaalsus võrreldes olemasolevate etalonidega, kuid oluliselt madalam määramatus krüotemperatuuridel (~77 K). Projekti tulemused võimaldavad erinevates rakendustes kasutada primaaretaloni põhimõtet, mis töötati välja ennustatava kvantefektiivse detektori jaoks projektis iMERA-Plus JRP T1.J2.3 qu-Candela.
"This project proposes a new and advanced means of realising the unit of optical power and other derived SI units, especially in the visible range, and a simplified traceability to the end-user through more practical and cost efficient techniques. This will be achieved by an optimised realisation of the primary standard for radiometry in the visible range with a 1 ppm uncertainty and by developing new techniques for providing traceability with an uncertainty below 100 ppm by accurately characterised filter radiometers for photometry and radiation thermometry. The best uncertainties of radiometric measurements reported so far are around 30 ppm for specific applications. In addition, traceability well below 1000 ppm uncertainty will be provided for fibre optics. The main goal of the project is an improved silicon detector primary standard for radiometry having approximately the same cost and functionality as the current transfer standard detectors, but with lower uncertainties at cryogenic temperatures (~77 K), enabling the primary standard to be built into different applications taking full advantage of the properties of Predictable Quantum Efficient Detectors (PQEDs) developed in the iMERA-Plus JRP T1.J2.3 qu-Candela. This project proposes a new and advanced means of realising the unit of optical power and other derived SI units, especially in the visible range, and a simplified traceability to the end-user through more practical and cost efficient techniques. This will be achieved by an optimised realisation of the primary standard for radiometry in the visible range with a 1 ppm uncertainty and by developing new techniques for providing traceability with an uncertainty below 100 ppm by accurately characterised filter radiometers for photometry and radiation thermometry. The best uncertainties of radiometric measurements reported so far are around 30 ppm for specific applications. In addition, traceability well below 1000 ppm uncertainty will be provided for fibre optics. The main goal of the project is an improved silicon detector primary standard for radiometry having approximately the same cost and functionality as the current transfer standard detectors, but with lower uncertainties at cryogenic temperatures (~77 K), enabling the primary standard to be built into different applications taking full advantage of the properties of Predictable Quantum Efficient Detectors (PQEDs) developed in the iMERA-Plus JRP T1.J2.3 qu-Candela.
TegevusProtsent
Alusuuring60,0
Rakendusuuring40,0